Ignition Coil Harness Installation

Feed our ignition coil harness into the DME box through the same rubber sheathing as the factory harness.

  • Lay the ignition coil harness over the valve cover and bunch the loose wire ends together.

  • Gently wrap tape around the loose wire ends to protect the terminals from damage.

  • Gently push the harness through the rubber sheathing until the taped end appear inside the DME box. Pull through about 1 foot of the harness.

Familiarize yourself with the terminals on the end of our ignition coil harness. You will find a heatshrink label on each wire with numbers from 1 to 6 circled in red below.

Ignition Coil - DME Connector - Pinning.png

Note the position labels on the connector below circled in green

Ignition Coil - DME Connector - Positions.png

Starting with the wire labeled number 1, insert the terminal into the corresponding position (1) in the connector you depinned above (DME ignition coil connector). Continue inserting all wires into their correct positions and recheck your work to ensure the wires have been inserted into the correct positions.